Investigation PE88074: 1978–1986 Spartan Spartan
- Status
- CLOSED
- Opened
- Jun 30, 1988
- Closed
- Oct 24, 1988
- Model years
- 1978–1986
Subject
Various brake problems
Component: Service brakes, hydraulic
Summary
Summary: recent rockwell defect report identified the following additional concerns:a: insufficient air pressure due to inadequate air compressor capcity;b: air horn plumbed into air system without pressure protection valve;c: brake imbalance caused by brake proportioning valves which reduce the front brake pressures. The above identified problems may result in heat checking and cracking of the rear brake drums.
An NHTSA investigation looks into whether a safety defect exists. Opening one is not a finding. Outcomes can include a recall, closure without action, or further inquiry.
About this data. Data from NHTSA (ODI) complaints, recalls, TSBs and investigations, updated Oct 29, 2026. Complaints are unverified consumer reports and may be duplicated or inaccurate.