NHTSA lists 9 recall campaigns for the 2000 Kenworth W900. A recall applies only to vehicles built within the affected range, so check your own VIN at nhtsa.gov/recalls. Repairs for recalls are free at a franchised dealer.
- Suspension › Front › HubCovers: Kenworth W900 1998–2001, Peterbilt 379 1998–2002, 387 1998–2002 +5 more
Reported issue: On certain trucks equipped with truck hub units manufactured by skf exclusively for use on arvinmeritor's ff98x series non-drive steer axles, the hub unit bearings can wear prematurely.
Possible consequence: Seizure of the bearings can cause wheel separation or wheel end fire.
Remedy: Dealers will replace all front axle hubs. Notification began july 16, 2003. The manufacturer has advised us that parts will not be available until september 2003. Owners who take their vehicles to an authorized dealer on an agreed upon service date and do not receive the free remedy with a reasonable time should…
- Steering › Linkages › Tie rod assemblyCovers: Kenworth W900 1999–2000, Peterbilt 379 1999–2000, Kenworth T800 1999–2000 +10 more
Reported issue: Heavy duty trucks equipped with trw tie rod ends on certain arvinmeritor and dana axles. Peterbilt will recall 1,434 vehicles equipped with arvinmeritor axles manufactured from december 11, 1999, to may 14, 2000, and from july 22 to september 30, 2000. Kenworth will recall 859 vehicles equipped with arvinmeritor vehicles manufactured from december 11, 1999, to may 23, 2000, and from july 27, 2000, to september 30…
Possible consequence: This can lead to premature wear with possible separation of the ball stud from the socket, increasing the risk of loss of control of the vehicle.
Remedy: Dealers will remove and replace all affected tie rods and drag links with different designed ends. Owner notification began july 15, 2002. Owners who take their vehicles to an authorized dealer on an agreed upon service date and do not receive the free remedy within a reasonable time should contact peterbilt at…
- Suspension › RearCovers: Kenworth W900 1998–2001, T800 1998–2001
Reported issue: On certain heavy duty trucks equipped with replacement dana spicer tandem drive axle models ds463 and ds521, installed on vehicles from may 1, 2001 through february 1, 2002, an undersized attachment weld may fracture without warning.
Possible consequence: The loss of this attachment to the vehicle chassis can adversely affect vehicle handling or driver control.
Remedy: Dana is conducting the owner notification and remedy for this campaign. The dealers will remove the suspect bracket, inspect the axle housing, and reweld the bracket to the axle housing. Owners who take their vehicles to an authorized dealer on an agreed upon service date and do not receive the free remedy within a…
- Electrical system › WiringCovers: Kenworth W900 2000, T800 2000, T600 2000 +1 more
Reported issue: On some heavy duty trucks equipped with alcoa fujikura ltd. (afl) power distribution boxes (pd box), the pd boxes were manufactured with insufficient torque applied to the nut of the main power feed-through stud.
Possible consequence: Insufficient torque can lead to (1) electrical arcing of the wires inside of the pd box, or (2) an interrupted power supply to the vehicle's electrical system, either of which can lead to a loss of vehicle electrical power and possibly vehicle control without warning.
Remedy: Dealers will inspect and tighten the nut on the main power feed-through stud. Owner notification began february 25, 2002. Owners who take their vehicles to an authorized dealer on an agreed upon service date and do not receive the free remedy within a reasonable time should contact kenworth at 1-425-828-5440.
- Steering › Linkages › Tie rod assemblyCovers: Kenworth W900 1999–2000, Peterbilt 379 1999–2000, Kenworth T800 1999–2000 +10 more
Reported issue: Vehicle description: heavy duty trucks equipped with trw tie rod ends on certain meritor axles. The tie rod and drag link ball stud ends contain bearings that are below the specified case depth and/or hardness.
Possible consequence: This can lead to premature wear with possible separation of the ball stud from the socket, increasing the risk of loss of control of the vehicle.
Remedy: Dealers will remove and replace all affected tie rods and drag links with different designed ends. Owner notification began october 24, 2001. Owners who take their vehicles to an authorized dealer on an agreed upon service date and do not receive the free remedy within a reasonable time should contact peterbilt at…
- SuspensionCovers: Kenworth W900 2000, Peterbilt 379 2000, 357 2000 +7 more
Reported issue: Vehicle description: heavy duty trucks equipped with chalmers 1000 series and 800 series suspension kits. These suspension kits may have insufficient penetration of the weld attaching the torque rod eye to the torque rod tube.
Possible consequence: Failure of the weld could result in separation of the eye and tube, causing a lock of axle retention, which could result in loss of vehicle control.
Remedy: Dealers will replace all chalmers fixed torque rods on these vehicles. Owner notification began july 27, 2001. Owners who take their vehicles to an authorized dealer on an agreed upon service date and do not receive the free remedy within a reasonable time should contact peterbilt at 1-940-591-4000 or kenworth at…
- Equipment › Other › LabelsCovers: Kenworth W900 1994–2001, T800 1994–2001
Reported issue: Vehicle description: heavy duty trucks equipped with meritor fg941 steer axles. The gross axle weight rating (gawr) was determined incorrectly and over-stated on the vehicle certification label. With the incorrect gawr listed, these labels do not meet the certification requirements of part 567, "requirements for manufacturers of motor vehicles." vehicles will be remedied either by assigning the proper weight rating…
Possible consequence: These vehicles would not be in compliance with federal regulations.
Remedy: Vehicles will be remedied either by assigning the proper weight rating or, if possible, by changing the necessary components to meet the currently assigned weight rating. Owner notification began june 22, 2001. Owners who take their vehicles to an authorized dealer on an agreed upon service date and do not receive…
- Suspension › Front › Control arm › Lower armCovers: Kenworth W900 1996–2001, T2000 1996–2001, T600 1996–2001 +3 more
Reported issue: Vehicle description: vehicles equipped with 54" rear axle spacing configuration of the airglide 200 suspension with the service application identified as logger, dump truck, or tanker. The rear suspension is regularly subjected to extreme articulation, resulting in flexing of the joint.
Possible consequence: Failure of the lower sway arm attaching bolts could result in loss of vehicle control.
Remedy: Dealers will replace the lower sway arm brackets. Owner notification began march 27, 2001. Owners who take their vehicles to an authorized dealer on an agreed upon service date and do not receive the free remedy within a reasonable time should contact kenworth at 1-425-828-5000.
- Electrical system › Wiring › Fuses and circuit breakersCovers: Kenworth W900 1999–2001, T800 1999–2001, T600 1999–2001 +1 more
Reported issue: Vehicle description: heavy duty trucks equipped with an optional firewall-mounted circuit breaker. The main cab power and battery power leads were attached incorrectly. This condition can result in the main cab power being unprotected.
Possible consequence: If a wiring short occurred anywhere along the cab power circuit, the available battery power could arc and cause subsequent damage to the vehicle or a fire.
Remedy: Dealers will inspect and correct the problem, as needed. Owner notification began february 26, 2001. Owners who take their vehicles to an authorized dealer on an agreed upon service date and do not receive the free remedy within a reasonable time should contact kenworth at 1-425-828-5000.
← All problems reported for the 2000 Kenworth W900
About this data. Data from NHTSA (ODI) complaints, recalls, TSBs and investigations, updated Oct 30, 2026. Complaints are unverified consumer reports and may be duplicated or inaccurate.