Recall 05V307000: 2005–2006 Tiffin Allegro BUS and 4 other models

Electrical system
Report received
Jul 5, 2005
Manufacturer
Tiffin motorhomes, inc.
Potentially affected
265vehicles
Model years
2005–2006

Check your own vehicle. A recall applies only to vehicles within the affected build range. Enter your VIN at nhtsa.gov/recalls. Recall repairs are free at a franchised dealer.

What NHTSA recorded

On certain motor homes containing a 50 amp transfer switch built by intellitec, the material used for the wire lugs was changed from nickel plated to copper lugs. The copper lugs are softer than the nickel plated and do not retain the torque of the screw that clamps the wire connector.

Possible consequence

When the torque is relaxed, the lugs can become loose resulting in excessive heat within the connected wire that could result in a fire.

Remedy

Dealers will replace the changeover box. The recall began on july 21, 2005. Owners may contact tiffin at 1-256-356-8661.