Recall 84V087000: Am general corporation
- Report received
- Aug 1, 1984
- Manufacturer
- Am general corporation
- Potentially affected
- 497vehicles
- Model years
- —
Check your own vehicle. A recall applies only to vehicles within the affected build range. Enter your VIN at nhtsa.gov/recalls. Recall repairs are free at a franchised dealer.
What NHTSA recorded
When tested according to the requirements of federal motor vehicle safety standard 301, "fuel system integrity". Ruptures in the fuel system occurred in a 30 mph frontal collision, allowing fuel to leak. The hardware used to attach the body to the chassis failed in the test. Movement of the vehicle"s body during the collision resulted in ruptures in fuel system.
Remedy
Additional hardware will be installed to tie the rear body to the rear bumper, a spacer will be placed in front of the fuel tank, and the fuel lines will be rerouted to prevent shearing. Work will be completed without charge.