Skip to content
Fuel systemPart report

1998 Ford F-250 Fuel system Problems

Complaints
6about this part
Share
11%of 56 total for the year
Median mileage
104,786miles
Trend
Not enough dataFewer than 15 complaints, too few for a reliable trend.

NHTSA recorded 6 complaints about the fuel system of the 1998 Ford F-250, 11% of the 56 complaints for this model year. Where a mileage was given, the median is 104,786 miles. 1 recall campaign on record is filed under a similar system.

Fewer than 15 complaints name this part, so treat the figures as a rough indication only.

Example complaints

Selected from NHTSA records; personal details are removed. They are consumer reports, not findings.

“On april 9th 2011 my fuel tank straps broke while driving at 45 MPH. The truck was pulled to the side of the road and the tank was hanging by the fuel lines and tank neck. The truck is a Ford F-250 light with a 24 1/2 gallon fuel tank, that has 102000 miles. I replaced both straps at a cost of $34.00. I painted the new straps to prevent future problems.”

NHTSA complaint #10399672, filed 2011-05, 102,000 miles

“The metal straps holding the gas tank on my 1998 f250 (regular duty) rusted to pieces one at a time until the last strap broke and the gas tank dropped on to the road. It is a miracle the tank didn't get wedged under the vehicle or explode from being dragged on the road.”

NHTSA complaint #10399622, filed 2011-05, 99,068 miles

“Ford F-250 4x4 Ford recall 11s21(NHTSA 11v385) fuel tank strap corrosion inspection and replacement was conducted. The fuel tank was also found to be rusted under the strap area only. After the old straps were removed the tank started to leak fuel and Ford nor the dealer would replace the tank. If the straps are covered for corrosion then the tank should be also due to the corrosion transferring to the tank surface. The dealer placed new straps over a rusted tank. The truck will need over $1200.00 in repairs for safe operation and to remedy the now leaking fuel.”

NHTSA complaint #10448582, filed 2012-02, 104,786 miles

“1998 Ford F-250 (early build) with 201,992 miles, had the gas tank strap rust and break resulting in the gas tank dropping to the pavement. The forward (front) gas tank strap failed and the gas tank fell to the pavement causing the release of approximately 22 gallons of fuel. The resulting spill required a cleanup by the local fire department. The spill cleanup resulted in a $453 charge by the fire department. The vehicle was towed to a repair shop at a cost of $112. The fuel tank and straps required replacement at a cost of $978.00. Total cost of event $1,500.”

NHTSA complaint #10399711, filed 2011-05, 201,992 miles

“Truck that was purchased brand new has a lpg tank assembly, consumer smells propane through the fresh air of the A/C system while set on vent, floor, and defrost, dealership has not been able to remedy the problem after many attempts.”

NHTSA complaint #876436, filed 2000-12

Related recalls

Related service bulletins

Fuel system: other model years

YearComplaintsShare of year
2014118%
201399%
2012208%
2011229%
2010710%
200924%
200863%
200747%
2006178%
20051913%
20041912%
20031311%
200285%
200142%
200082%
1999417%
1998611%
19972910%
1996159%
1995169%
19941311%
19933728%
19923227%
19913028%
19904036%
19893027%
19881118%
1987411%
198638%
1985210%
1984110%

Other parts of the 1998 Ford F-250

Suspension
14 complaints
Brakes
11 complaints
Body and structure
9 complaints
Engine cooling
8 complaints
Tires
4 complaints
Air bags
3 complaints
Steering
3 complaints
Visibility (wipers, defrost, mirrors)
3 complaints
Electrical system
2 complaints
Exterior lighting
2 complaints
Transmission and drivetrain
2 complaints
Vehicle speed control
2 complaints

← All problems reported for the 1998 Ford F-250

About this data. Data from NHTSA (ODI) complaints, recalls, TSBs and investigations, updated Oct 31, 2026. Complaints are unverified consumer reports and may be duplicated or inaccurate.

To check a specific vehicle for open recalls, use its VIN at nhtsa.gov/recalls. Methodology